EYE+ Studio 5.2
EYE+ Studio 5.2
Released on 2025-04-14
New Features
Asyfill smart hopper fill ratio
With the introduction of the Asyfill smart hopper, it is now possible to obtain more feedback from your hopper. This release introduces a new parameter to the TCP/IP protocol: hopper_fill_ratio and two new error codes (427, 428).
Check the documentation to see how to integrate this new feature.
Improvements
General
EYE+ has been updated with improvements to its core systems and user interface. Users may notice minor aesthetic differences, but the overall experience remains consistent.
Acquisition Settings
The Custom region of interest (ROI) can now be defined freely across the entire image. It is no longer restricted to an image-centered area.
Acquisition Lighting Settings
The selection of the lights in Acquisition lighting settings has been improved to better support setups using an Asycube without a backlight installed.
Camera Configuration
Improved pattern recognition during the Vision Calibration. This is particularly noticeable when performing a vision calibration using a frontlight.
Purge
An overlay has been added to the Asycube Purge card when the settings cannot be changed.
Resolved issues
General
Fix the handling of negative and decimal numbers in various input fields. The behavior is now more user-friendly.
Camera Configuration
Fixed and issue where the settings in Camera Configuration Set Lighting would not be used when performing the Vision Calibration.
Dashboard
Resolved an issue where the dashboard could freeze or show errors due to delays in image loading.
Purge
Start purge: In TCP/IP and Fieldbus, error 407 is used when trying to start the purge using a remote recipe on an unconnected remote FTP server.
Hand-eye calibration
Fix invalid migration of the custom ROI in the hand-eye calibration recipe. This even affected a recipe without a custom ROI defined.