Warnung
You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.1 .Camera
Camera connection
Connect the camera M12 Ethernet connector to the EYE+ Controller Camera PoE port with a PoE Ethernet cable. The Ethernet cable should be at least Cat6 S/FTP. The camera LED should start flashing green after a moment.
Warnung
This cable is supplied by Asyril in different lengths (2m, 5m, 10m, 15m, 20m). Always use the cable supplied by Asyril to ensure good camera performance. Otherwise, it may result in communication loss with the camera.
LED behavior |
Camera status |
---|---|
LED off |
Not powered |
Red |
Error |
Flashing red |
Powered but no Ethernet link established |
Flashing green |
Powered, Ethernet link established, but no network traffic |
Green |
Powered, Ethernet link established and there is a network traffic |
Camera specifications
The camera uses X-coded 8 position M12 connector for Ethernet communication.
The default Camera port configuration on EYE+ Controller side is presented in Tab. 16.
Ethernet port |
IP address |
Subnet mask |
---|---|---|
Camera |
192.168.21.1 |
255.255.255.0 |