Warnung

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.0 .

Camera

Camera connection

Connect the camera M12 Ethernet connector to the EYE+ Controller Camera PoE port with a PoE Ethernet cable. The Ethernet cable should be at least Cat6 S/FTP. The camera LED should start flashing green after a moment.

Warnung

This cable is supplied by Asyril in different lengths (2m, 5m, 10m, 15m, 20m). Always use the cable supplied by Asyril to ensure good camera performance. Otherwise, it may result in communication loss with the camera.

Tab. 15 Connection status of the camera

LED behavior

Camera status

LED off

Not powered

Red

Error

Flashing red

Powered but no Ethernet link established

Flashing green

Powered, Ethernet link established, but no network traffic

Green

Powered, Ethernet link established and there is a network traffic

Camera specifications

The camera uses X-coded 8 position M12 connector for Ethernet communication.

The default Camera port configuration on EYE+ Controller side is presented in Tab. 16.

Tab. 16 EYE+ Controller default Camera Ethernet configuration

Ethernet port

IP address

Subnet mask

Camera

192.168.21.1

255.255.255.0