Warnung
Sie lesen eine alte Version dieser Dokumentation. Wenn Sie aktuelle Informationen wünschen, schauen Sie bitte unter 5.0 .Plugin installation
Step 1: Check robot software
The plugin uses socket messaging over TCP/IP protocol. You must have the optional „User Socket Msg“ software (R648) installed on your robot to enable socket communication.
If it is correctly installed, the following information should be displayed on the IPendant touch under the path
MENU/STATUS/Version ID/Media
and select NEXT/ORDER FI
.
Wichtig
If the software is not installed on your robot, please contact FANUC support to get it.
Step 2: Download the plugin
Download the plugin zip file fanuc-eyeplusPlugin-version.zip here. It must contain 9 p-code files (extension .pc).
eye_check_last_error.pc
eye_comm1.pc
eye_comm2.pc
eye_configure.pc
eye_get_part.pc
eye_prepare_part.pc
eye_raw_command.pc
eye_start_production.pc
eye_stop.pc
Step 3: Install the plugin on your robot
Unzip the fanuc-eyeplusPlugin-version file and save the 9 files on a USB key.
Warnung
Your USB key must be formatted to FAT or FAT32 (File Access Tables) to be detected by the controller.
Connect the USB key to the IPendant touch of the robot. On the IPendant touch, go to MENU/FILE/UTILE/Set Device/Select
your device
. Then, for each file, select the file and click LOAD
.
Step 4: Check if the files are correctly installed
From the IPendant touch, go to SELECT/[TYPE]/KAREL Progs
. Then check if the 9 files are listed in this window as
shown in Abb. 206.
Bemerkung
The version of the plugin you downloaded must be displayed on the side.