EYE+ is supplied with a calibration plate specific to your Asycube size.

Fig. 21 Calibration plate for Asycube 50 to 530
Purpose
Vision calibration plate is used to perform the camera configuration that will:
Check the camera orientation.
Define the region of interest (ROI).
Display information in millimeters/inches rather than pixels in the interface.
Correct distortion of the lens.
Mounting vision calibration plate
Follow these two steps to mount the vision calibration plate:
Remove Asycube plate from the Asycube.
Place the vision calibration plate.
Once your vision calibration plate is mounted, please make sure that:
The vision calibration plate is flat.
The vision calibration plate has no play.
The vision calibration plate is mounted in the correct orientation: the Asyril logo must face upwards.
Warning
The Asycube 380/530 vision calibration plates must be tightened using the screws in each corner.
Asycube 50/80

Fig. 22 Procedure to remove Asycube 50/80 plate

Fig. 23 Procedure to mount the vision calibration plate on Asycube 50/80
Asycube 240

Fig. 24 Procedure to remove Asycube 240 plate

Fig. 25 Procedure to mount the vision calibration plate on Asycube 240
Asycube 380/530

Fig. 26 Procedure to remove Asycube 380/530 plate

Fig. 27 Procedure to mount the vision calibration plate on Asycube 380/530