Communication with EYE+ is done using a simple text-based ASCII protocol. The client sends a command, EYE+ responds with a status code followed by a message.
Important
ASCII command must be followed by a unique end of line delimiter as specified in
TCP Configuration, the default configuration is LF (i.e \n, ASCII code 0x0A).
From TCP terminal, the character is automatically sent and does not need to be specified.
EYE+ command
The command must be written in lower case with underscored separations (e.g. get_parameter). A space must be placed between the command and the parameter and between the parameter and the value. Refer to section Commands for all available commands.
- without parameter or value - <command>\n 
- with parameter and no value - <command>␣<parameter>\n 
- with parameter and value - <command>␣<parameter>␣<value>\n 
EYE+ response
EYE+ responds to each client’s command using a code to inform the client of the command’s status. The response always proceeds in the same way:
<response_code>␣<further information>\n
If the response holds more than one line, the number of lines is added after <response_code>.
<response_code>␣<n>␣<further information>\n
<further information>\n
...
<further information>\n
| 
 | Signification | 
|---|---|
| 200 | The command ran successfully | 
| 201 <n> | The command ran successfully and contains <n> lines in the output | 
| 4xx | Error from the Client | 
| 5xx | Error from the Server (i.e. EYE+) | 
Error codes
In case of an error, the error code is followed by a unique description of the error.
Client error codes
- 401
- The received command is unknown 
- 402
- The given argument is not valid for this command 
- 403
- System is not in production state - Ensure that a recipe has been started in production. 
- 404
- The given parameter does not exist 
- 405
- A get_part command is already active, most likely using a different connection 
- 406
- The requested transition to a different system state is not allowed 
- 407
- The recipe identifier is not found in the system - Ensure you used the correct recipe identifier and that the recipe is valid for production. 
- 408
- The recipe is not ready to be used in production - Edit the recipe and complete the teaching wizard. 
- 409
- The system is not in a valid state 
- 410
- No valid license found - Ensure that a valid license has been installed. 
- 411
- All internal concurrent connections are exhausted - Reduce the number of concurrent connections to the TCP/IP protocol. 
- 412
- The purge option is not enabled in the Asycube settings - Navigate to configuration > Asycube and enable the purge option. 
- 413
- System is not in purge state - Ensure that the purge has been started. 
- 414
- A purge command is already active, most likely using a different connection. 
- 415
- Invalid duration for purge command - Ensure that the argument is between 1 and 30000 (inclusive). 
- 416
- Not enough points registered to perform hand-eye calibration - You must register 4 vision points and 4 robot points before calibrating. 
- 417
- Requested point is not set - You must register the calibration point at least once before calling get_calibration_point. 
- 418
- Purge flap couldn’t be closed - Make sure nothing is impeding the flap and the actuator is still functional. 
Server error codes
- 501
- Timeout occurred while trying to find valid parts - Check that there is a correct number of parts on the plate, the plate is not empty nor overfilled. 
- 502
- An Asycube alarm was raised while trying to find valid parts, causing the command to timeout. 
- 503
- Timeout occurred while the system was waiting on can_take_image to become true 
- 510
- get_part was interrupted by a stop/abort, most likely received on a different connection 
- 511
- The system is not able to connect to the Asycube - Verify the cabling, the power supply and the IP settings. 
- 512
- A communication error occurred while sending/receiving a message to/from the Asycube - Verify the cabling and the power supply. 
- 513
- The command sent to the Asycube returned an error (ErXXXXX) - Logs should contain more information. Check also the Asycube error codes. 
- 514
- Error while turning the back light on or off - Verify the cabling, power supply and connection to the Asycube. 
- 515
- Error while turning the front light on or off - Logs might contain more information. 
- 516
- The camera is not connected - Logs should contain more information. Verify the cabling. The led should be green. 
- 517
- The purge flap could not be opened/closed within the allowed time - Check that the purge flap can be operated properly, that no part is stuck. Check the sensor on the side. 
- 518
- The purge was interrupted by a stop, most likely received on a different connection 
- 519
- No calibration available - You must calculate the hand-eye calibration before saving or using it. 
- 520
- No pick point match - No match found in last image analysis. 
- 596
- Internal error related to the production - Logs should contain more information about the problem. 
- 597
- Internal error related to the vision - Logs should contain more information about the problem. 
- 598
- Internal error related to the feeder - Logs should contain more information about the problem. 
- 599
- Internal error related to system - Logs should contain more information about the problem.