You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.0 .Parameters
Parameters described here are additions or modifications to the standard Parameters. They can be used in production when working with a dualfeeding recipe.
Parameter |
Type 1 |
Additional value |
Valid value |
Default value |
---|---|---|---|---|
R/W |
string |
int |
0 |
|
RO |
string |
int |
0 |
- 1
RO: Read Only; R/W: Read and Write
multi_n_parts_prepared
It returns the number of parts currently prepared for the given type (a
or b
).
This parameter takes a mandatory additional value corresponding to the part type (a
or b
).
get_parameter multi_n_parts_prepared a
200 1
get_parameter multi_n_parts_prepared b
200 2
multi_part_quantity
It is the number of parts of a specific type requested by prepare_part and get_part each time it takes an image. If this number of parts is not found during image acquisition, then the get_part or prepare_part will start again (vibration + image acquisition) until this number of parts is found.
This parameter takes a mandatory additional value corresponding to the part type (a
or b
).
Note
Refer to get_part to see how multi_part_quantity can be combined with different part types.
get_parameter multi_part_quantity a
200 0
set_parameter multi_part_quantity b 4
200
get_parameter multi_part_quantity b
200 4