Avertissement

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.1 .

Power supply

Power connection

Plug in the provided power cable to the EYE+ Controller power input and to the specified power supply (see Tableau 11).

Once it is done, the EYE+ Controller will start automatically. On system startup, the status LED is off. It can take 2 minutes to start. This could take longer in case of restart after upgrade (around 5 minutes).

Note

The system will automatically reset after some time (around 30min) if the application does not start properly.

When the system enters the ready state, LED blinks slowly (1Hz).

To turn off the EYE+ Controller, unplug the power cable.

Note

The power cable is provided in the EYE+ kit.

Power specifications

Tableau 11 summarizes the EYE+ Controller power specifications.

Tableau 11 EYE+ Controller power specifications

Characteristic

Value

Voltage

24V DC PELV (+- 5%)

Current Power

12.5A max

EYE+ connector is a male XLR3. Connector and cable specifications are presented in Tableau 12 and in Tableau 13.

Tableau 12 Male XLR3 power connector (EYE+ side)

Pin

Signal

EYE+ Controller connector

1

24V DC PELV

power_connector_img

2

GND

3

EARTH

Tableau 13 Power cable internal wires (power supply side)

Number

Signal

Internal wires

EYE+ Controller connector

1

24V DC PELV

Red

power_cable_img

2

GND

Black

3

EARTH

Drain wire (black) 1

1

The drain wire has a smaller diameter than the GND wire.