Avertissement

Vous lisez une ancienne version de cette documentation. Si vous souhaitez obtenir des informations actualisées, veuillez consulter 5.0 .

Plugin functions

You can start programming with the EYE+ plugin on the IPendant touch through TPE programs.

Important

The camera configuration and hand-eye calibration must be done from the EYE+ Studio interface before executing any commands. If you do not know how to proceed, please refer to the Assistant de configuration de la caméra and Assistant d’étalonnage main-œil sections.

To call a plugin command from a TPE program, you must use the CALL command and select the program through [INST]/CALL/CALL program/COLLECT/KAREL Progs.

Important

The EYE_COMM1 and EYE_COMM2 commands are private programs. These programs are used internally to manage the communication with your EYE+. Please do not call these two programs.

The following 7 commands are basic programs allowing to create a simple and easy to integrate pick and place.

  • EYE_CONFIGURE

  • EYE_STOP

  • EYE_START_PRODUCTION

  • EYE_GET_PART

  • EYE_PREPARE_PART

  • EYE_RAW_COMMAND

  • EYE_CHECK_LAST_ERROR

EYE_CONFIGURE(client1 = 1, client2 = 2)

Paramètres

  • client1 - is the client number of the first client you configured in step Plugin configuration. The parameter must be an integer between 1 and 8. If no parameter is given as input, client1 will be set to 1.

  • client2 - is the client number of the second client you configured in step Plugin configuration. The parameter must be an integer between 1 and 8. This parameter must not be the same as the first one. If no parameter is given as input, client2 will be set to 2.

Description

This command must be called at the beginning of your program to specify the clients used by the communication.

Remarque

If you have not configured the clients correctly in step Plugin configuration, you will get the following error 602 Client configuration error and the communication between your robot and your EYE+ will not start.

Exemple d’utilisation

1: EYE_CONFIGURE(1, 2)
3: EYE_CHECK_LAST_ERROR
4: IF (R[21:Asyril-EYELastEr] = 602) THEN
5: MESSAGE('Not well configured')
6: ENDIF

EYE_START_PRODUCTION(recipe_id)

Paramètres

  • recipe_id - the recipe’s unique identifier. The parameter must be an integer between 1 and 65535.

Description

This command must be called to start EYE+ in production state using the right recipe.

Exemple d’utilisation

1: EYE_CONFIGURE(1, 2)
2: EYE_START_PRODUCTION(12345)
3: EYE_CHECK_LAST_ERROR
4: IF (R[21:Asyril-EYELastEr] = 0) THEN
5: MESSAGE('EYE+ is in production')
6: ENDIF
7: EYE_STOP('production')

EYE_STOP(state)

Paramètres

  • state - either production, recipe_edition, camera_configuration or handeye_calibration. The parameter must be a string.

Description

This command is used to stop an EYE+ state and stop the communication on both clients. You must always end your program with an EYE_STOP('production').

Avertissement

If you miss the call at the end of your program, you will need to do a fnct/ABORT (ALL) with the IPendant touch to stop the communication when starting another program.

Exemple d’utilisation

 1: EYE_CONFIGURE(1, 2)
 2: EYE_STOP('recipe_edition')
 3: EYE_STOP('camera_configuration')
 4: EYE_STOP('handeye_calibration')
 5: EYE_STOP('production')
 6:
 7: EYE_START_PRODUCTION(12345)
 8: ...
 9:
10: EYE_STOP('production')
11: EYE_CHECK_LAST_ERROR
12: IF (R[21:Asyril-EYELastEr] = 0) THEN
13: MESSAGE('EYE+ is in ready state')
14: ENDIF

EYE_GET_PART(pos_reg = 20)

Paramètres

  • pos_reg - (optional) is the position register number to which the coordinates of the found part will be written. If no parameter is specified as input, the default position register used is PR[20:Asyril-EYEPos]. The parameter must be an integer.

Renvoie

The returned part is stored in the input position register.

Only the X, Y and R components are overwritten in the specified position register. You have to add the other components (Z, W, P) yourself according to your robot setup. These missing components can be assigned by hand or by using the assignment operator in your program.

Avertissement

If you do not assign the last components, the position will not be reachable by your robot.

../../../_images/position20_issue.png

Fig. 211 Position register if you do not fill in the components Z, W, P

Description

This command is used to request one part from EYE+. This is a blocking command, meaning it will keep going until it gets a response from EYE+.

Exemple d’utilisation

 1: EYE_CONFIGURE(1, 2)
 2: EYE_START_PRODUCTION(12345)
 3:
 4: //Assign the other components of the part position to be reachable
 5: PR[20:Asyril-EYEPos, 3] = 15
 6: PR[20:Asyril-EYEPos, 4] = (-180)
 7: PR[20:Asyril-EYEpos, 5] = 0
 8:
 9: EYE_GET_PART
10: EYE_CHECK_LAST_ERROR
11: IF (R[21:Asyril-EYELastEr] = 0) THEN
12: MESSAGE('EYE+ found a part')
13: ENDIF
14: EYE_STOP('production')

EYE_PREPARE_PART

Description

This command is used to request one part from EYE+. This command is not a blocking command. The part coordinates can be retrieved later with the EYE_GET_PART command.

Exemple d’utilisation

 1: EYE_CONFIGURE(1, 2)
 2: EYE_START_PRODUCTION(12345)
 3:
 4: //Assign the other components of the part position to be reachable
 5: PR[20:Asyril-EYEPos, 3] = 15
 6: PR[20:Asyril-EYEPos, 4] = (-180)
 7: PR[20:Asyril-EYEpos, 5] = 0
 8:
 9: EYE_PREPARE_PART
10:
11: ...
12:
13: EYE_GET_PART
14: EYE_CHECK_LAST_ERROR
15: IF (R[21:Asyril-EYELastEr] = 0) THEN
16: MESSAGE('EYE+ found a part')
17: ENDIF
18: EYE_STOP('production')

EYE_RAW_COMMAND(cmd, str_reg = 20, client = 1)

Paramètres

  • cmd - is the raw command to send to EYE+. This parameter must be a string.

  • str_reg - (optional) is the register number to which the response to the raw command will be written. If no parameter is specified as input, the default string register used is the SR[20:Asyril-EYERawRes] register. The parameter must be an integer.

  • client - (optional) is the client number that will be used to send the command. The parameter must be an integer whose value is equal to 1 or 2. If no parameter is specified as input, the default client is the 1.

    Remarque

    Client 1 is the first client you entered in the EYE_CONFIGURE command and client 2 is the second client you entered.

    Avertissement

    If you want to specify the client number, you must also specify the str_reg. If you don’t, you may have unexpected issues.

Renvoie

The raw response of the command is stored in the string register str_reg.

Description

This function is used to send raw commands to EYE+. Refer to chapter Commandes to know what kind of commands can be sent.

Avertissement

If you send the command EYE_RAW_COMMAND('set_parameter part_quantity 2'), the EYE_GET_PART command will provide only the first part coordinates in the position register. However, if you use a EYE_RAW_COMMAND('get_part') command, the string response will contain all the part coordinates.

Exemple d’utilisation

1: EYE_CONFIGURE(1, 2)
2: EYE_RAW_COMMAND('start production 12345`)
3: IF (SR[20:Asyril-EYERawRes] = '200') THEN
4: MESSAGE('EYE+ is in production')
5: ENDIF
6: EYE_STOP('production')

EYE_CHECK_LAST_ERROR(int_reg = 21)

Paramètres

  • int_reg - (optional) is the register number used to store the last detected error. The parameter must be an integer. If not specified, the register used is the R[21:Asyril-EYELastEr] register.

    Avertissement

    Make sure the int_reg parameter is not a reserved register. Refer to Tableau 37 for further information.

Renvoie

The last error detected is stored in the register number int_reg.

Description

This function is used to check if an error has occurred.

  • If no error has occurred, the output is equal to 0.

  • If an EYE+ error has occurred, the output is equal to one of the error codes listed in Codes d’erreur (error type 4xx or 5xx).

  • If a plugin error has occurred, the output is one of the following errors displayed in Tableau 35 (error type 6xx).

Tableau 35 Plugin errors

Error code

Signification

601

Communication error

602

Client configuration error

603

Connection failed

604

Timeout occurred

605

Wrong client numbers

606

Wrong input parameters

699

Generic error

Once the error is returned as output from the function, the error is cleared internally (value set to 0).

Exemple d’utilisation

 1: EYE_CONFIGURE(1, 2)
 2: EYE_GET_PART
 3: EYE_CHECK_LAST_ERROR
 4: IF (R[21:Asyril-EYELastEr] = 403) THEN
 5: MESSAGE('Production subsystem has not been started')
 6: ENDIF
 7: EYE_CHECK_LAST_ERROR
 8: IF (R[21:Asyril-EYELastEr] = 0) THEN
 9: MESSAGE('Now the error is cleared')
10: ENDIF
11: EYE_STOP('production')