Warning

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.1 .

Safety information

Warning

../_images/caution.png

Asyril cannot be held liable for damage to property or injuries to people caused by failure to follow the instructions specified in the “Safety instructions” paragraph. It is the customer’s responsibility to inform the personnel concerned.

Note

../_images/note.png

All dimensions and measurements in this manual are expressed in millimeters (mm).

General instruction

Danger

../_images/danger.png

Be sure that all power sources and other cables to the unit are disconnected before working on the product.

Danger

../_images/danger_electric.png

Do not unscrew the housing of the system controls. Serious injury or death could result from electric shock. Only authorized personnel from Asyril SA are allowed to access this part of the system for maintenance or for repair.

Danger

../_images/danger.png

Never modify the product. Unauthorized modification may cause the product to malfunction, resulting in injury, electric shock, fire, etc.

Danger

../_images/danger.png

Do not use the product in a place where the main unit or controller may come in contact with water or oil droplets.

Danger

../_images/danger_burning.png

The active elements inside the EYE+ make the surfaces shown in the picture below (blue surface) capable of heating up to 50°C in extreme use cases. It is the responsibility of customers to document their own application and instruct employees on procedures to avoid contact with these surfaces.

../_images/hot_surface.png

Fig. 1 Surface of EYE+ that could become hot (in blue)

Disposal

When the product reaches the end of its service life, it must disposed of in accordance with regulations concerning industrial waste.

Note

../_images/note.png

All applicable laws, regulations, and standards must be observed when disposing of the product.

Maintenance and repair

Warning

../_images/caution.png

No maintenance operation must be performed inside the product. To perform internal maintenance operations, please contact Asyril. Failure to respect this requirement will invalidate the warranty.

Danger

../_images/danger.png

Never use the system when it is damaged. Check that you have resolved the problem before restarting the machine.

Note

../_images/note.png

Cleaning the optical parts: Visually inspect the optical parts (camera, lens, lighting, etc.) and clean if necessary.

Transportation, handling and installation

Packaging of the product, transportation and handling

The product must be transported in accordance with the specifications indicated on the package (top, bottom, fragile, etc.). In addition, the following points must be strictly respected:

  • Take adequate precautions during handling.

  • Do not climb on the package.

  • Never place heavy objects on the package.

  • Take particular care to avoid damaging the product during transportation.

Unpacking instructions

Before unpacking:

  • Ask the transporter to be present at the time of unpacking.

  • Pay particular attention to the external condition of the product.

  • If any damage is noted, do not sign the receipt and contact Asyril immediately.

Note

../_images/note.png

If the products received do not match your delivery note, or are delivered in poor condition, do not sign the receipt and contact Asyril as soon as possible.

Installation and storage environment

The EYE+ Controller system must be used under the following conditions:

Table 1 EYE+ Controller standard specifications

Characteristic

Value

Storage Temperature

+5°C to 40°C

Operating Temperature

+5°C to 40°C

Humidity

Operating: 30% to 85%

Ingress Protection

IP30

The camera must be used under the following conditions:

Table 2 Camera standard specifications

Characteristic

Value

Storage Temperature

-30 to 60°C

Operating Temperature

-20 to 55°C ambient

Humidity

Operating: 20% ~ 80%, relative, non-condensing

Shock and Vibration

DIN EN 60068-2-27, DIN EN 60068-2-64, DIN EN 60068-2-6

Ingress Protection

IP67