Warning

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.0 .

Hopper interface

Selecting the hopper

We generally recommend using the Asyfill for your flexible application. However, the choice of your hopper also depends on your complete setup.

The Asycube has two integrated digital/analogue outputs. In cases where more outputs are needed (e.g. in the context of multi-feeding with three or four parts) Asyril proposes a GPIO cable to connect up to four hoppers to the GPIO connector of the EYE+ Controller. Note that the purge on an Asycube 240 also requires an Asycube output.

This table will help you select the right product for your multi-feeding application.

Table 33 Hopper selection for a multi-feeding application

Asycube size

Number of parts

Recommended hopper

Possible hopper size

Asycube 240

2

Asyfill smart hopper

1L

2 (with purge)

Standard hopper with GPIO cable

1L

3

Standard hopper with GPIO cable

1L

4

Standard hopper with GPIO cable

1L

Asycube 380

2

Asyfill smart hopper

1L, 2L, 3L, 7L 1

3

Standard hopper with GPIO cable

1L, 2L, 3L

4

Standard hopper with GPIO cable

1L, 2L, 3L

Asycube 530

2

Asyfill smart hopper

1L, 2L, 3L, 7L, 14L 1

3

Standard hopper with GPIO cable

1L, 2L, 3L

4

Standard hopper with GPIO cable

1L, 2L, 3L

1 Multi-feeding with two parts possible on different short sides of the Asycube only, see Fig. 255.
../../_images/asyfill_m_cube_dual_short.png

Fig. 255 Multi-feeding with two parts on different short sides

For more details on how to mount the hoppers around the Asycube, see the Hoppers section in the Asycube Documentation.

Connecting the hopper

Asyfill and other analogue hoppers

Analogue hoppers such as the Asyfill must be connected directly to the analogue outputs of your Asycube.

Digital hoppers

Digital hoppers such as Asyril standard hopper can either be connected to the digital outputs of the Asycube or to the EYE+ Controller using a GPIO cable.

GPIO cable

The cable connects the GPIO connector of the EYE+ Controller on one side and the M8 cables from the hoppers on the other side.

The M8 cables from the hoppers are connected to a distribution box. This box has a 3 meters long cable ending with an 8-position female GPIO connector with 16 contacts (2 rows), 3.5 mm pitch, that is plugged to the GPIO connector on the EYE+ Controller.

../../_images/gpio_cable.png

Fig. 256 Multi-feeding cable

The distribution box has mounting holes that can be used to fasten the box:

../../_images/gpio_distribution_box_schematic.png

Fig. 257 Distribution box schematic

Important

Only connect an Asyril hopper using the supplied M8 cable to the distribution box. Do not connect any other hopper or use any other cable. Failure to comply with this instruction may result in permanent damage to the EYE+ Controller or to your own device.