Transportation, handling and installation

Packaging of the product, transportation and handling

The product must be transported in accordance with the specifications indicated on the package (top, bottom, fragile, etc.). In addition, the following points must be strictly respected:

  • Take adequate precautions during handling.

  • Do not climb on the package.

  • Never place heavy objects on the package.

  • Take particular care to avoid damaging the product during transportation.

Unpacking instructions

Before unpacking:

  • Ask the transporter to be present at the time of unpacking.

  • Pay particular attention to the external condition of the product.

  • If any damage is noted, do not sign the receipt and contact Asyril immediately.

Note

If the products received do not match your delivery note, or are delivered in poor condition, do not sign the receipt and contact Asyril as soon as possible.

Installation and storage environment

The EYE+ Controller system must be used under the following conditions:

Table 1 EYE+ Controller standard specifications

Characteristic

Value

Storage Temperature

+5°C to 40°C

Operating Temperature

+5°C to 40°C

Humidity

Operating: 30% to 85%

Ingress Protection

IP30

The camera must be used under the following conditions:

Table 2 Camera standard specifications

Characteristic

Value

Storage Temperature

-30 to 60°C

Operating Temperature

-20 to 55°C ambient

Humidity

Operating: 20% ~ 80%, relative, non-condensing

Shock and Vibration

DIN EN 60068-2-27, DIN EN 60068-2-64, DIN EN 60068-2-6

Ingress Protection

IP67