警告

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.0 .

Network

Access the network configuration through CONFIGURATION and Network.

Network interfaces settings

From here, you can change the configuration settings of Robot and Configuration ports. Make sure that your configuration settings are compatible with the configuration of the devices connected to EYE+. They must be on the same network.

../../_images/network_configuration_robot.png
../../_images/network_configuration_config.png

図 108 IP settings of Robot and Configuration ports


ROBOT port

The default settings of the Robot port are presented in 表 23.

表 23 EYE+ Controller default Robot Ethernet configuration

Ethernet port

IP address

Subnet mask

Port

Robot

192.168.0.50

255.255.255.0

7171

This configuration means that the IP address of your robot/PLC must be between 192.168.0.1 and 192.168.0.254 except 192.168.0.50.

If this IP address range is not compatible with your robot/PLC configuration, you can change the IP address and subnet mask of the EYE+ Controller to be on the same network as your robot/PLC.

CONFIG port

The default settings of the Configuration port are presented in 表 24.

表 24 Default EYE+ Configuration port settings

Ethernet port

Default IP address

Default subnet mask

Default gateway

Configuration

192.168.1.50

255.255.255.0

0.0.0.0

This default configuration means that your computer can only connect via direct connection and the IP address of your computer's port must be between 192.168.1.1 and 192.168.1.254 except 192.168.1.50.

If you want to connect EYE+ to your company network via indirect connection, you need to change the IP address, subnet mask and default gateway of the Configuration port of EYE+ to match your company network configuration.

It is also possible to use the DHCP configuration mode. The DHCP server will automatically give an IP address, subnet mask and gateway to the EYE+ Configuration port.

注釈

To find out the settings applied by the DHCP server, you must ask your company's IT department which IP address has been linked.