警告

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.0 .

set_parameter <parameter> <value>

Parameters

  • parameter - refer to 表 27 for a list of valid parameters

  • value - refer to 表 27 for a list of valid values.

表 28 List of parameters

Parameter

Type 1

Valid value

Default value

state

RO

string

<none>

recipe

RO

string

<none>

timeout

R/W

float

30.0s

image_after_send

R/W

true/false

false

is_prepared

RO

true/false

false

n_parts_prepared

RO

int

0

part_quantity

R/W

int

1

1

RO: Read Only; R/W: Read and Write

Returns

  • 200 <response>, returns 200 followed by value of the parameter specified if command succeeded, else refer to error codes

Description

Assign a value to the parameter specified as the command argument. Valid parameters are described in 表 28. Refer to section Parameters to have more information about each parameter.

注釈

The parameters can only be changed when EYE+ is in production state.

Usage example

start_production 12345
set_parameter timeout 10.5