Power supply

Power connection

Connect the Power connector of the EYE+ Controller to the specified power supply (see Table 12) with the provided power cable.

Once it is done, the EYE+ Controller will start automatically. When the system starts up, the Status LED is off. Start-up may take up to 2 minutes. It may take longer when restarting the system after an upgrade (approx. 5 minutes) of if the Asycube or the camera is not connected.

Note

The system will automatically reset after some time (around 30min) if the application does not start properly.

When the system enters the ready state, Status LED blinks slowly (1Hz).

To turn off the EYE+ Controller, unplug the power cable.

Note

The power cable is provided in the EYE+ kit.

Power specifications

Table 12 summarizes the EYE+ Controller power specifications.

Table 12 EYE+ Controller power specifications

Characteristic

Value

Voltage

24V DC PELV (+- 5%)

Current Power with frontlight

6.5A max

Current Power without frontlight

2.5A max

Note

Those values may change with the addition of new hardware functionality (e.g. : GPIO)

EYE+ connector is a male XLR3. Connector and cable specifications are presented in Table 13 and in Table 14.

Table 13 Male XLR3 power connector (EYE+ side)

Pin

Signal

EYE+ Controller connector

1

24V DC PELV

power_connector_img

2

GND

3

EARTH

Table 14 Power cable internal wires (power supply side)

Number

Signal

Internal wires

EYE+ Controller connector

1

24V DC PELV

Black, labeled 1

power_cable_img

2

GND

Black, labeled 2

3

EARTH

Yellow / Green