You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.1 .Power supply
Power connection
Connect the Power connector of the EYE+ Controller to the specified power supply (see Table 12) with the provided power cable.
Once it is done, the EYE+ Controller will start automatically. When the system starts up, the Status LED is off. Start-up may take up to 2 minutes. It may take longer when restarting the system after an upgrade (approx. 5 minutes) of if the Asycube or the camera is not connected.
Note
The system will automatically reset after some time (around 30min) if the application does not start properly.
When the system enters the ready state, Status LED blinks slowly (1Hz).
To turn off the EYE+ Controller, unplug the power cable.
Note
The power cable is provided in the EYE+ kit.
Power specifications
Table 12 summarizes the EYE+ Controller power specifications.
Characteristic |
Value |
---|---|
Voltage |
24V DC PELV (+- 5%) |
Current Power with frontlight |
6.5A max |
Current Power without frontlight |
2.5A max |
Note
Those values may change with the addition of new hardware functionality (e.g. : GPIO)
EYE+ connector is a male XLR3. Connector and cable specifications are presented in Table 13 and in Table 14.
Pin |
Signal |
EYE+ Controller connector |
---|---|---|
1 |
24V DC PELV |
|
2 |
GND |
|
3 |
EARTH |
Number |
Signal |
Internal wires |
EYE+ Controller connector |
---|---|---|---|
1 |
24V DC PELV |
Black, labeled 1 |
|
2 |
GND |
Black, labeled 2 |
|
3 |
EARTH |
Yellow / Green |