EYE+ Studio 4.1
EYE+ Studio 4.1.1
Released on 2023-07-12
Resolved Issues
General
Fix an issue where, under specific conditions, a new recipe could not be saved.
Fix an issue where some images would be missing from a recipe after importing it and rebooting the EYE+ Controller.
EYE+ Studio 4.1.0
Released on 2023-06-15
New Features
Remote Storage
EYE+ now has the ability to connect to a compatible FTP server to store recipes. With this feature, one EYE+ Controller can have access to more memory to store even more recipes. Please get familiar with Storage and Remote storage to get started with this feature.
General
Starting with version 4.1, your EYE+ automatically advertises its IP address and other information. An external tool is available to locate your EYE+, see EYE+ Locator.
Camera Configuration
4. Center position, 5. Set Asycube orientation, 6. Adjust focus: It is now possible to zoom in the live views. This feature is particularly useful when centering the camera.
6. Adjust focus: A focus gauge was added in the live view. This new tool allows better refinement of the focus.
Recipe wizard
4.2 Pick Point Positioning, 5.2 Pick Angle Positioning: The help geometries drawn on these two steps are now saved inside the recipe and will be displayed again when editing the recipe.
4.2 Pick Point Positioning: The dimensions of the help geometries are now displayed.
5.2 Pick Angle Positioning: Help geometries have been added to allow precise alignment between the angle and the features of the part.
Improvements
EYE+ Studio
Camera and Lighting cards have now been merged into a new card, see Vision.
Recipes: The maximum number of recipes is now computed dynamically (at least 150 MiB must be available to create a new recipe). Additionally a warning is shown if 90% of the storage is full.
The detection of a blocked live view has been improved and the interface will now properly display an error or use a fallback depending on the situation.
EYE+ Studio will now block the user from browsing the application when the system is in Migration Error by displaying a dialog inviting them to check the camera and Asycube connection.
Fieldbus
Interrupting a
Get Part
with aStop Production
will no longer yield the error 510.
Resolved Issues
General
Fixed an issue where closing a recipe could sometimes display an error message.
Camera Configuration
Fixed an issue where exporting the full-resolution image using the right-click menu resulted in an error.
Dashboard
Fixed an issue where the time to first part was wrongly computed when parallel vibration mode was used.
Production
Fixed an issue where sending a stop purge while the system is in Production would make the system behave out of specifications.
Recipe wizard
Fixed an issue where exporting an image in the recipe wizard was causing the name to contain
undefined
instead of the recipe identifier.1.2 Image Acquisition: Fixed an issue where re-acquiring the initial image database would not clear all models in a multi-model recipe.
3.3 Candidate Classification: Fixed an issue when classifying candidates in a multi-model recipes would display a prompt to apply the classification before all models actually had the required number of samples.
7. Vision Results: Fixed an issue where the menu for exporting the images was not enabled on this page.