Vision

Access the vision configuration through CONFIGURATION and Vision.

../../_images/vision_configuration_interface.png

Fig. 189 Vision configuration interface

This interface allows you to configure various settings related to vision such as the camera and lighting.

Camera configuration

The camera configuration card informs you about the current state of the Camera configuration wizard and allows you to open it.

Three variants of the interface are possible:

  • No camera configuration performed (Fig. 190)

../../_images/no_camera_configuration.png

Fig. 190 No camera configuration performed

  • Camera configuration in progress (Fig. 191)

../../_images/camera_configuration_in_progress.png

Fig. 191 Camera configuration in progress

  • Camera configuration already performed (Fig. 192)

../../_images/camera_configuration_access_done.png

Fig. 192 Camera configuration already performed

If the camera configuration was already performed (Fig. 192), some information regarding last camera configuration is available:

  • Date of last configuration: Date of when the last camera configuration was performed.

  • Working distance: Measured distance between the Asycube and the camera’s lens.

  • RMS Error: RMS error of last distortion correction.

  • px/mm scale or px/in scale: Scale between pixels and millimeters/inches.


Access camera configuration wizard

Click on START CAMERA CONFIGURATION WIZARD or OPEN CAMERA CONFIGURATION WIZARD to access the Camera configuration wizard.

Camera information

This card indicates whether the camera is connected or not. This can be useful to troubleshoot some issues you may have with your system.

Acquisition lighting settings

This card gives you the possibility to configure backlight and frontlight acquisition settings:

  • by providing maximum and minimum exposure time in milliseconds

  • by providing exposure time increment (interval) in milliseconds

  • by indicating which lighting is installed on the system

This settings will define the available acquisition settings that you can choose when editing a recipe.

Note

Exposure time is the time during which the camera is exposed to light when acquiring images. The longer the exposure time, the brighter the image is. You must choose an exposure time range that ensures good part detection.

Tip

First, try using the default settings. If the images are too dark, return to this page and increase the minimum and maximum exposure times. If the images are too bright, decrease the minimum and maximum exposure times.

For example, configuration from Fig. 193 enables following image acquisition settings:

  • Backlight: 1, 2, 3, 4, …, 20ms

  • Frontlight: None because lighting is disabled

../../_images/acquisition_lighting.png

Fig. 193 Acquisition lighting settings configuration

Note

If your system does not have a backlight or a frontlight, disable it with the switch on top right.

Important

Changing these settings will affect all your recipes when re-starting image acquisition. It will not modify the settings already saved if they are unchanged.