Warning
You are reading an old version of this documentation. If you want up-to-date information, please have a look at 5.0 .1.1 Part Spreading
Before starting, make sure that the Asycube multi-feeding production plate is correctly mounted.
Then place a reasonable number of each part on their respective side evenly distributed on the production plate. A general rule to find the appropriate part number is to have 1/3 of each plate section covered by parts.
Spread the parts randomly but make sure to have all possible orientations of the parts represented:
Good orientation: The orientation of the part required for the robot pickup.
Bad orientation: All other orientations of the part that are not suitable for robot pick-up.
Tip
Leave some parts in contact (a group of 2 parts is sufficient). This will ensure that groups of parts are rejected during the candidate detection stage.
1.2 Image Acquisition
This step is the exact same as with a single part recipe. For more information, please refer to 1.2 Image Acquisition.